(Created page with "== Abstract == Shock tracking, as an alternative method to shock capturing, aims to generate a mesh such that element faces align with shock surfaces and other non-smooth fea...") |
|||
(6 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | == | + | == Summary == |
+ | |||
+ | We present an original goal-oriented inverse method for model parameter identification. Initially developed in [1], it is based on dual analysis and consists in a modified version of the concept of Constitutive Relation Error. It stands out from standard deterministic inverse methods by its formulation, as it focuses on the accurate prediction of a specific quantity of interest, and aims at automatically identifying and updating the model parameters involved in its computation alone. To further reduce the CPU time of the multi-query inversion process, that also involves coupled time forward/backward systems to solve, the goal-oriented inverse method is beneficially complemented with model order reduction, using the Proper Generalized Decomposition (PGD) technique [2]. Eventually, the goal-oriented method is also employed for optimal sensor placement (experimental design), in order to drastically reduce the number of sensors which need to be deployed for the objective of the simulation. | ||
+ | |||
+ | The proposed method is here applied and illustrated with transient heat transfer models encountered in building thermal problems. Inverse analysis with such models is a compulsory but costly task for the reliable evaluation of building thermal properties, accurate prediction of energy consumption, and therefore optimal driving of renovation strategy of power control. It usually involves a large number of parameters but a restricted number of available sensing data. In this framework, the goal-oriented method is first integrated in a software chain containing CAD and thermal dynamic simulation tools. Performance is then numerically evaluated on several test cases with real experiments. In particular, a two-story building of the Sense-City equipment with controlled climate scenarios and in-situ sensors is considered, with various quantities of interest [3]. It is shown that for all these and using the goal-oriented strategy, very few model parameters actually need to be updated, and little sensing information is necessary, without sacrificing accuracy. It is then a tool of choice for such applications. | ||
− | |||
− | |||
== Video == | == Video == | ||
{{#evt:service=cloudfront|id=53995|alignment=center|filename=65.mp4}} | {{#evt:service=cloudfront|id=53995|alignment=center|filename=65.mp4}} | ||
− | + | ||
== Document == | == Document == | ||
<pdf>Media:Draft_Garcia_330241719A_IDC6_65.pdf</pdf> | <pdf>Media:Draft_Garcia_330241719A_IDC6_65.pdf</pdf> |
We present an original goal-oriented inverse method for model parameter identification. Initially developed in [1], it is based on dual analysis and consists in a modified version of the concept of Constitutive Relation Error. It stands out from standard deterministic inverse methods by its formulation, as it focuses on the accurate prediction of a specific quantity of interest, and aims at automatically identifying and updating the model parameters involved in its computation alone. To further reduce the CPU time of the multi-query inversion process, that also involves coupled time forward/backward systems to solve, the goal-oriented inverse method is beneficially complemented with model order reduction, using the Proper Generalized Decomposition (PGD) technique [2]. Eventually, the goal-oriented method is also employed for optimal sensor placement (experimental design), in order to drastically reduce the number of sensors which need to be deployed for the objective of the simulation.
The proposed method is here applied and illustrated with transient heat transfer models encountered in building thermal problems. Inverse analysis with such models is a compulsory but costly task for the reliable evaluation of building thermal properties, accurate prediction of energy consumption, and therefore optimal driving of renovation strategy of power control. It usually involves a large number of parameters but a restricted number of available sensing data. In this framework, the goal-oriented method is first integrated in a software chain containing CAD and thermal dynamic simulation tools. Performance is then numerically evaluated on several test cases with real experiments. In particular, a two-story building of the Sense-City equipment with controlled climate scenarios and in-situ sensors is considered, with various quantities of interest [3]. It is shown that for all these and using the goal-oriented strategy, very few model parameters actually need to be updated, and little sensing information is necessary, without sacrificing accuracy. It is then a tool of choice for such applications.
Published on 17/05/21
Submitted on 17/05/21
Licence: CC BY-NC-SA license
Are you one of the authors of this document?